home send mail contacts
Ru   En         
ASE Group

Industrial computers

 

Industrial computers

PAMIR® series

Pamir-VK

Pamir-RM

Pamir-BS

Press

Software

Medicine

Telecommunication

Web-design              NEW !

Informational projects

About ASE Group

Information

Partners

Contacts

Job opportunity

News

01-Jul-2017
Ver. 7 of medical sofware is released more...
26-Aug-2015
The shipment of equipment for nuclear power plant more...
15-Jan-2015
The shipment of equipment for nuclear power plant more...
01-Sep-2014
Ver. 6 of medical sofware is released more...

 


PAMIR-VK


Servers of PAMIR® series


Servers PAMIR-VK are intended for execution of main information tasks:

  • performing of calculations
  • data exchange
  • information storage

Main technical data *


FUNCTIONALITY

Processor unit

from 1 up to 4, on everyone 1-2 processors of Intel, Ultrasparc - 32-64-digits, 500-3000 MHz, RAM - up to 32 GB on processor unit

HDD

1-6 disk drives 200 GB/
RAID 5 levels (6 disk drives) 1000 GB

Interfaces

Centronics, RS-232, RS-485, Ultra-Wide SCSI-2, USB, Ethernet - up to 24 ports 10/100/1000 TX/FX UTP/FO

Videoadapter

resolution up to 1280õ1024, 16 million colors at screen refresh frequency not less than 60 Hz

System software

on base of Solaris, Red Hat Linux
 

Standards, protocols, services, packets

POSIX, X-Windows, C ANSI, TCP/IP, FTP, NFS, TELNET, Motif

Auto-start

self-acting start of applied software at turn-on or reboot

Monitoring

- diagnostics and control of components via SNMP protocol
 
- supervision and exception handling of applied software

Test software

- write / read on HDD
- data exchange via Ethernet
- displaying graphic and text information on the monitor
- usage of operational resources and processor load
- output of the graphic and test information to printer
- operation in real time, response to interruptions from the keyboard and manipulator, priorities of task execution
- execution of applied software

RELIABILITY

Reliability of components

self-diagnostics,  remote monitoring and reconfiguring of equipment

Average mean-time-between- failures

not less than 50000 h

Mean time of restoring

no more than 1 h

Availability

Single products - not less than 0,99993-0,99995 for various implementations
In the doubled configuration - not less than 0.9999999991-0.999999995

Average service life

not less than 30 years on condition of changeover of separate modules and units which have worked out the operational life

PROTECTION AGAINST EXTERNAL INFLUENCES

Vibro- & shock stability

- at sine-wave vibrations with intensity 0.12 g (1.2 m/s²) over the range 1-100 Hz in a powered state, 0.25 g (2.5 m/s²) over the range 1-100 Hz in the switched off state
- single impact with maximal amplitude of peak shock acceleration up to 3 g (30 m/s²) with duration 10 ms (Ì38 according to GOST 17516)

Seismic stability

operability at earthquake with intensity 0.5 g (5 m/s²) over the range 1-35 Hz

Electromagnetic compatibility and noise-immunity

- group of implementation III for electromagnetic environment of middle rigidity with operation performance criterion "A" at effect of interferences according to GOST Ð50746 (including IEC 1000-4-2, 3, 4, 5, 8, 9, 11)
- emission of man-made interferences - class "A" according to GOST 29216, GOST Ð50033

Interruption of external power supply

up to 20 min, automatic stop and restart

Atmospheric conditions

 
- working values:
air temperature from +10 up to +40°Ñ, air relative humidity of 80 % at 25°Ñ
- limiting values:
air temperature from +1 up to +45°Ñ, air relative humidity of 98 % at 35°Ñ

Access to dangerous parts, hit of external hard subjects, water

IP20/IP21/IP30

SAFETY

Fire safety

according to GOST 12.1.004, probability of fire origination in products less than 0.000001 per year

Protection against electric-shock hazard

01 class according to GOST 12.2.007.0

Protection against unauthorized access

physical protection, control of access to  hardware and software components

TRANSPORTATION AND STORAGE

Transportation

on any distances by automobile and  railway transport (in obturated transport facilities), water-carriage (in holds of ships) or aiviation (in pressurized bays)

Requirements

air temperature from -20°Ñ up to + 50°Ñ, in the other respects - demands to storage 3 (OZh3) or 6 (OZh2) according to GOST 15150

SERVICE CONDITIONS

Power supply

220 (+10 %, -15 %) V
50 (+2 %, -3 %) Hz

Power consumption

no more than 1000 V·A

OVERALL DIMENSIONS

AND MASS

Width õ depth õ height õ mass (no more)

depending of model
 
* Remarks: these data can vary for different implementations. Exact information - in the technical documentation of the company.

General view of some implementations

 

VK-01R-08

VK-01R-08.01

VK-01R-08.02

VK-01R-08.04
 

VK-01R-08.07

VK-01R-09.02

VK-01R-09.03

VK-01R-10
 
 

© 1996-2019 ASE Group. All rights reserved.